EXINDA Aura 2.5 kW Ceiling Suspended All-in-One Heat Pump


Uncluttered rooms. Comfort tailored to your space.

Create a welcoming interior in compact flats, modular homes and hotel rooms. The AURA 2.5 kW All-in-One heat pump sits discreetly above the ceiling, leaving walls and floors available for furniture and everyday living. Heating and cooling are controlled within each space, with optional heat-recovery ventilation and no separate outdoor condenser.

2.5 kW class2.64 kW rated heating
Optional ERVAdd fresh-air ventilation when needed
No separate outdoor condenserOutdoor intake and exhaust through the wall
Wall controller includedEveryday room comfort control

Ceiling-Suspended Heat Pump Specifications

ModelICMPCGFF1AYE
System typeCeiling-suspended all-in-one heat pump; ERV optional
Rated cooling capacity2.49 kW at 35°C DB / 23.9°C WB outdoor and 26.7°C DB / 19.4°C WB indoor
Rated heating capacity2.64 kW at 8.3°C DB / 6.1°C WB outdoor and 21.1°C DB / 15.6°C WB indoor
Low-temperature heating2.42 kW at -5°C; 2.05 kW at -15°C
Optional ERV ventilation airflow25.0–47.2 L/s; 42.5 / 33.0 / 25.0 L/s high / medium / low
Indoor supply airflow105.7–167.5 L/s at 80 Pa available external static pressure
Power supply208–240 V / 50 Hz / 1 Ph, hardwired
MCA / MOP15 A / 20 A, heat pump plus electric heater
Maximum electric auxiliary heat1.5 kW
Compressor / refrigerantBLDC twin-rotary inverter / R32 A2L, 0.5 kg charge
Compressor operating range-15 to 42.8°C outdoor
Exterior connectionsIntake and exhaust, 203 × 254 mm rectangular
Filters in the documented ERV configuration2 × MERV 13 non-washable (outdoor air); 2 × MERV 4 washable (return); 1 × MERV 4 washable (condenser)
Optional ERV energy-recovery coreCross-flow, non-washable; exhaust defrost
Sound pressure45 dB(A) at 1 m; 40 dB(A) at 3 m, ceiling installed with gypsum board beneath, high heating airflow
Dimensions (W × D × H)1122 × 948 × 283 mm
Net weight74.8 kg
ControllerWall-mounted digital touch controller included; 24 V dry contact included; optional Wi-Fi and BACnet
Certification

CE CB SAA MEPS approved

Heating, Cooling and Optional ERV Performance

Use the capacity at the project design temperature. Heat-pump outdoor airflow and optional ERV fresh-air delivery are separate air systems. ERV rows below apply only to the documented optional configuration.

Operating pointCapacity / airflowInput or efficiencyTest condition
Cooling rating2.49 kW987 W; EER 2.53 W/W35°C DB / 23.9°C WB outdoor; 26.7°C DB / 19.4°C WB indoor
Heating rating2.64 kW1,040 W; COP 2.538.3°C DB / 6.1°C WB outdoor; 21.1°C DB / 15.6°C WB indoor
Low-temperature heating2.42 kW1,150 W; COP 2.10-5°C DB / -10.6°C WB outdoor; 21.1°C DB / 15.6°C WB indoor
Minimum compressor condition2.05 kW1,350 W; COP 1.52-15°C DB / -16.1°C WB outdoor; 21.1°C DB / 15.6°C WB indoor
Optional ERV heating test, low airflow30.2 L/s net outdoor air30 W; 77% SRE / 80% ASRE0°C inlet supply
Optional ERV heating test, high airflow43.4 L/s net outdoor air46 W; 73% SRE / 77% ASRE0°C inlet supply
Optional ERV cold test20.3 L/s net outdoor air30 W; 44% SRE / 45% ASRE-25°C inlet supply
Optional ERV cooling test30.7 L/s net outdoor air30 W; 63% total / 65% adjusted total recovery35°C inlet supply
Indoor duct design105.7–167.5 L/s80 Pa available external static pressure

AURA Technical Documents

View the 3.5 kW AURA with integrated ERV

Compare all AURA heat pump models

AURA Selection Questions

Is this a good fit for a compact flat or guest room?

Its concealed layout keeps the floor clear in compact flats, guest accommodation and modular homes. Choose the optional ERV where this system will also provide fresh air, or coordinate it with the building’s existing ventilation.

Should I use the ceiling void or a floor-standing unit?

A ceiling unit is useful when retaining floor space matters. Allow room above the finished ceiling for the cabinet, ducts and servicing. Where the ceiling void is too shallow, consider a vertical unit in a suitable indoor service area.

Where can the unit go when planning a home or refurbishment?

A utility area can offer a useful position away from sleeping and sitting areas. Coordinate supports, vibration isolation, duct routes and an accessible service opening before the ceiling is finished.

How does the system connect through the external wall?

Separate air-intake and discharge ducts run to external openings or a coordinated louvre arrangement. This avoids a separate outdoor condenser. Include the openings, insulation and separation in the façade design.

Should I add heat-recovery ventilation?

Select the ERV option when this unit is to supply fresh air as well as heating and cooling. If ventilation is already provided separately, the heating-and-cooling configuration may suit the project.

How much ceiling space does the installation need?

The cabinet is 283 mm high. The ceiling layout also needs room for supports, ducts, drainage and access panels. Keep these allowances in the installation plan so the equipment stays hidden and remains accessible.

What access should the installer leave for servicing?

Position the access panel at the service side, with room to remove filters and reach electrical components and the condensate drain. Keep the opening clear of joinery, fixed finishes and other services.

Can drainage work where a gravity fall is difficult?

Optional external condensate-pump interlock provides an alternative arrangement. Plan the pump and pipe route together, keeping both accessible for cleaning and maintenance.

Can one development combine different sizes and layouts?

Yes. Compact flats, larger dwellings and guest accommodation can use different AURA sizes or installation formats. Send the project location, floor plans and unit mix for model selection and technical support.

Partner With EXINDA

Distributors & Dealers

Expand your HVAC offering with EXINDA heat pumps and ventilation systems, backed by product training and technical support.

Engineering Firms & Contractors

Get the performance data, submittals and engineering support you need to select equipment and move your project forward.

HVAC Brands

Bring your product ideas to market with EXINDA’s engineering, testing and manufacturing expertise.