EXINDA Aura 3.5kW All-in-One Heat Pump ERV (HPERV)


A comfortable home. A considered use of space.

Bring heating, cooling and fresh air into compact flats and terraced homes with one discreet ceiling system. AURA 3.5 kW combines a slim 282 mm cabinet with built-in energy recovery, helping preserve usable space and a tidy exterior. Concealed ducts carry air to living rooms and bedrooms, while planned service access makes routine care practical.

3.5 kW cooling · 4.0 kW heatingRated heat-pump capacity
71–229 m³/h fresh airIntegrated energy-recovery ventilation
282 mm cabinet heightCeiling-ducted installation
No separate outdoor condenserOutdoor intake and exhaust connect through the wall

Core Specifications

ModelICMPCGFF1AYE
System typeCeiling-ducted all-in-one heat pump energy recovery ventilator
Rated heat-pump cooling / heating3.5 kW / 4.0 kW at the stated rating conditions
Balanced ERV ventilation airflow71–229 m³/h; 229 / 153 / 71 m³/h high / medium / low
Indoor supply airflow at 75 PaApproximately 730 m³/h cooling / 1150 m³/h heating at high speed
Outdoor heat-pump circuit airflow at 105 PaApproximately 1500 m³/h cooling / 1350 m³/h heating
Power supply208–240 V / 50–60 Hz / 1 Ph, hardwired
Maximum auxiliary heat / maximum input3 kW / 3900 W
MCA / MOP20 A / 30 A
CompressorBLDC twin-rotary inverter
Refrigerant / chargeR32 (A2L) / 1.07 kg
Heat-pump operating range−15 to 43°C outdoor
Auxiliary-heat operating range−35 to 43°C outdoor
Sound pressure48 dB(A) at 1 m / 43 dB(A) at 3 m
Net dimensions (W × D × H)1168 × 1160 × 282 mm
Net / gross weight98 kg / 158 kg
ControllerWall-mounted digital touch controller included; Wi-Fi and BACnet optional
CertificationCE CB SAA MEPS approved

Sound values were measured with the unit ceiling-mounted, gypsum board below and piping connected, in high heating-airflow mode.

Heating and Cooling Performance

Operating pointHeat-pump capacityInput / efficiencyRating condition
Cooling3.5 kW1465 W; EER 2.40 W/W35°C DB / 24°C WB outdoor; 27°C DB / 19°C WB indoor
Heating4.0 kW1687 W; COP 2.438°C DB / 6°C WB outdoor; 21°C DB / 16°C WB indoor
Low-temperature heating2.9 kW1650 W; COP 1.78−5°C DB / −11°C WB outdoor; 21°C DB / 16°C WB indoor
Minimum compressor condition1.7 kW1350 W; COP 1.30−15°C DB / −16°C WB outdoor; 21°C DB / 16°C WB indoor

Below −15°C outdoor temperature, the compressor is disabled and the unit uses electric auxiliary heat only, up to 3 kW. Check the calculated heating load at the project design temperature before selection.

The submittal also reports ERV recovery contributions of 0.44 kW in cooling at 35°C and 0.73 kW in heating at 8°C. These are recovery contributions, not additional compressor capacity.

Ventilation and Airflow

Fresh-air ventilation, room air distribution and outdoor heat exchange use separate airflow ratings, shown below.

Air systemAirflow / ESPEvidence or design note
Balanced ERV ventilation229 / 153 / 71 m³/hHigh / medium / low; ERV operating range −15 to 43°C DB
Indoor supply — coolingApproximately 730 m³/h at 75 PaHigh-speed rated point; use the fan curve for other duties
Indoor supply — heatingApproximately 1150 m³/h at 75 PaHigh-speed rated point; use the fan curve for other duties
Outdoor circuit — coolingApproximately 1500 m³/h at 105 PaHeat-pump heat-exchange circuit, not fresh-air delivery
Outdoor circuit — heating1350 m³/h at 105 PaHeat-pump heat-exchange circuit, not fresh-air delivery
ERV heating test at 0°C — low70 m³/h; 27 W77% SRE / 80% ASRE
ERV heating test at 0°C — high150 m³/h; 82 W73% SRE / 77% ASRE
ERV cooling test at 35°C70 m³/h; 26 W67% sensible total / 69% adjusted total efficiency
Ventilation testing: Ventilation performance tested in accordance with CAN/CSA-C439 and HVI rating procedures.

MERV 13 indoor-air filters: 2, non-washable. MERV 4 return-air filters: 2, washable. MERV 4 condenser filter: 1, washable. The cross-flow heat exchanger is non-washable; the unit includes auto-balancing and exhaust defrost.

Installation and Controls

Outdoor intake / exhaust305 × 203 mm / 254 × 203 mm rectangular
Minimum intake-to-exhaust separation1.25 m
Room return / bathroom exhaustØ203 mm / Ø152 mm round
Supply duct options711 × 203 mm rectangular or 4 × Ø152 mm round
Outdoor duct insulationMinimum 20 mm with vapor barrier
Flexible outdoor connectorsApproximately 100 mm long and insulated for condensation control
Main service access corridor1516 mm minimum
Service opening depth575 mm minimum
Air-inlet service opening406 × 406 mm
Electrical compartment clearance406 mm minimum
Side clearance50 mm minimum
Controller cable5 m standard, 26 AWG; 55 m maximum
Condensate drainsTwo NPS 1/4 in. (6.35 mm) drains; individual P-traps and minimum 1% slope required

Confirm the final coordination drawing, ceiling structure, duct resistance, filter access, electrical access and condensate routing before construction.

AURA Technical Documents

Compare all AURA heat pump models

AURA Selection Questions

Can the system supply the sitting room and bedrooms?

Yes. A branched supply-duct layout carries air to the individual rooms, with a return route to the unit. Your designer allocates airflow to suit how each room is used.

Should I use the ceiling void or a floor-standing unit?

A ceiling unit is useful when retaining floor space matters. Allow room above the finished ceiling for the cabinet, ducts and servicing. Where the ceiling void is too shallow, consider a vertical unit in a suitable indoor service area.

Where can the unit go when planning a home or refurbishment?

A utility area can offer a useful position away from sleeping and sitting areas. Coordinate supports, vibration isolation, duct routes and an accessible service opening before the ceiling is finished.

How does the system connect through the external wall?

Separate air-intake and discharge ducts run to external openings or a coordinated louvre arrangement. This avoids a separate outdoor condenser. Include the openings, insulation and separation in the façade design.

How are fresh air and bathroom extract arranged?

The integrated ERV supplies fresh air and recovers energy from outgoing air. A bathroom extract route can form part of this arrangement, with the airflows and controls coordinated for the home.

How much ceiling space does the installation need?

The cabinet is 282 mm high. Allow additional space for supports, duct connections, drainage and the service opening when setting the finished ceiling level. Its concealed position preserves usable floor space in compact homes.

What access should the installer leave for servicing?

Position the access panel at the service side, with room to remove filters and reach electrical components and the condensate drain. Keep the opening clear of joinery, fixed finishes and other services.

Can drainage work where a gravity fall is difficult?

Optional external condensate-pump interlock provides an alternative arrangement. Plan the pump and pipe route together, keeping both accessible for cleaning and maintenance.

Can one development combine different sizes and layouts?

Yes. Compact flats, larger dwellings and guest accommodation can use different AURA sizes or installation formats. Send the project location, floor plans and unit mix for model selection and technical support.

Partner With EXINDA

Distributors & Dealers

Expand your HVAC offering with EXINDA heat pumps and ventilation systems, backed by product training and technical support.

Engineering Firms & Contractors

Get the performance data, submittals and engineering support you need to select equipment and move your project forward.

HVAC Brands

Bring your product ideas to market with EXINDA’s engineering, testing and manufacturing expertise.