ERV Manufacturer — Breeze Energy Recovery Ventilators

A tight house needs fresh air, and bringing it in should not cost the heat or humidity already inside. Breeze ERVs recover both from the outgoing air and keep running through Canadian winters with no electric preheater. They are already installed in single-family homes, multifamily buildings and condos across Canada.

EXINDA Breeze HVI-certified energy recovery ventilator

Five Breeze ERV Models, Each for a Different Space

Model Mounting Net supply at 0.4 in. w.g. SRE (HVI) HVI ID
ICMBCNF1AYE — Breeze 50–100 CFM Ceiling / horizontal 95 CFM 77% 2005353
ICMBCOFF1AYE — Breeze 49–133 CFM Ceiling / horizontal 136 CFM 74% 2005359
ICMBCOFF1AYS — Breeze 42–170 CFM, field adjustable Ceiling / horizontal 170 CFM 86% 2005500
IWMBCOOF1AYE — Breeze 54–100 CFM Wall / horizontal 102 CFM 72% 2005360
IWMBCOFF1AYE — Breeze 57–152 CFM Wall / horizontal 153 CFM 77% 2005356

Net supply is the HVI-certified value at 0.4 in. w.g.; SRE is the HVI-rated value at 0 °C. All five models are certified to UL 1812 and CSA C439 under CSA certificate 80227354. Compare the Breeze ERV range.

What Installers Notice

The 42–170 CFM model is 9.4 in. thick and fits ceiling spaces a standard ERV cabinet will not. Auto-balancing holds supply and exhaust together at the rated external static pressure. A mirror configuration takes duct runs from the other side. There is no condensate drain to route. Side-port and top-port versions are available, with two washable MERV 8 filters as standard. Four models use recirculation defrost; the compact 50–100 CFM model uses exhaust defrost.

EXINDA Breeze ERV installation

Built for Cold Winters

HVI rates the 42–170 CFM model at 86 % SRE at 0 °C and 67 % at −25 °C, tested over 72 hours at the cold end of the program.

Cold-climate ERV check: what to verify below −25 °C

Working with EXINDA

Distributors get product documents, sample units, training and spare parts. Contractors and engineers can start with four things: location, dwelling type, design ventilation rate and where the unit will mount. We send back the model selection and submittal. HVAC brands can discuss their own range built on the Breeze platform.

Request ERV selection support