EXINDA Aura 8,500 Btu/h Ceiling Suspended All-in-One Heat Pump


Small spaces. Complete comfort.

Make room for comfort in hotels, studios and modular homes. EXINDA AURA 8,500 Btu/h All-in-One heating and cooling stays concealed above the ceiling, leaving floor space free and interiors uncluttered. Add optional energy-recovery ventilation to suit the building’s fresh-air plan, with individual room control and no separate outdoor condenser.

8,500 Btu/h cooling9,000 Btu/h rated heating
Optional ERVAdd fresh-air ventilation when needed
No separate outdoor condenserOutdoor intake and exhaust through the wall
Wall controller includedEveryday room comfort control

Ceiling-Suspended Heat Pump Specifications

ModelICMBCNF1AYE
System typeCeiling-suspended all-in-one heat pump; ERV optional
Rated cooling capacity8,500 Btu/h at 95 °F DB / 75 °F WB outdoor and 80 °F DB / 67 °F WB indoor
Rated heating capacity9,000 Btu/h at 47 °F DB / 43 °F WB outdoor and 70 °F DB / 60 °F WB indoor
Low-temperature heating8,250 Btu/h at 23 °F; 7,000 Btu/h at 5 °F
Optional ERV ventilation airflow53–100 CFM; 90 / 70 / 53 CFM high / medium / low
Indoor supply airflow224–355 CFM at 0.32 in. w.g. available external static pressure
Power supply208–240 V / 60 Hz / 1 Ph, hardwired
MCA / MOP15 A / 20 A, heat pump plus electric heater
Maximum electric auxiliary heat1.5 kW
Compressor / refrigerantBLDC twin-rotary inverter / R32 A2L, 1.21 lb charge
Compressor operating range5 to 109 °F outdoor
Exterior connectionsIntake and exhaust, 8 × 10 in. rectangular
Filters in the documented ERV configuration2 × MERV 13 non-washable (outdoor air); 2 × MERV 4 washable (return); 1 × MERV 4 washable (condenser)
Optional ERV energy-recovery coreCross-flow, non-washable; exhaust defrost
Sound pressure45 dB(A) at 1 m; 40 dB(A) at 3 m, ceiling installed with gypsum board beneath, high heating airflow
Dimensions (W × D × H)44-3/16 × 37-5/16 × 11-1/8 in.
Net weight165 lb
ControllerWall-mounted digital touch controller included; 24 V dry contact included; optional Wi-Fi and BACnet
Certification

CSA certified. AHRI certification in progress.

CSA certificate 80287910 · Canada and US · CSA product listing

Heating, Cooling and Optional ERV Performance

Use the capacity at the project design temperature. Heat-pump outdoor airflow and optional ERV fresh-air delivery are separate air systems. ERV rows below apply only to the documented optional configuration.

Operating pointCapacity / airflowInput or efficiencyTest condition
Cooling rating8,500 Btu/h987 W; EER 8.64 Btu/W95 °F DB / 75 °F WB outdoor; 80 °F DB / 67 °F WB indoor
Heating rating9,000 Btu/h1,040 W; COP 2.5347 °F DB / 43 °F WB outdoor; 70 °F DB / 60 °F WB indoor
Low-temperature heating8,250 Btu/h1,150 W; COP 2.1023 °F DB / 13 °F WB outdoor; 70 °F DB / 60 °F WB indoor
Minimum compressor condition7,000 Btu/h1,350 W; COP 1.525 °F DB / 3 °F WB outdoor; 70 °F DB / 60 °F WB indoor
Optional ERV heating test, low airflow64 CFM net outdoor air30 W; 77% SRE / 80% ASRE32 °F inlet supply
Optional ERV heating test, high airflow92 CFM net outdoor air46 W; 73% SRE / 77% ASRE32 °F inlet supply
Optional ERV cold test43 CFM net outdoor air30 W; 44% SRE / 45% ASRE−13 °F inlet supply
Optional ERV cooling test65 CFM net outdoor air30 W; 63% total / 65% adjusted total recovery95 °F inlet supply
Indoor duct design224–355 CFM—0.32 in. w.g. available external static pressure

AURA Technical Documents

View the 12,000 Btu/h AURA with integrated ERV

Compare all AURA heat pump models

AURA Selection Questions

Where does this model fit best?

It suits hotel rooms, studios and compact modular homes where floor space and a clean interior matter. Concealed ductwork connects the unit to the room, with optional ERV when fresh air is required from the same system.

How do I choose between ceiling and floor-standing installation?

Choose ceiling installation when keeping the floor clear is a priority and there is space above the finished ceiling for the unit, ducts and service access. A vertical model is an alternative when ceiling depth is limited and a dedicated indoor equipment position is available.

Where should the equipment sit within the home?

A utility or laundry area can be a practical location, keeping the indoor compressor away from bedrooms and main seating areas. Coordinate vibration isolation, duct routes and a service opening before finishing the ceiling.

What needs to connect to the outside of the building?

Separate outdoor intake and discharge ducts connect the indoor unit to exterior air openings or a coordinated louver assembly. There is no separate outdoor condenser. Plan the openings, duct insulation and separation as part of the façade design.

Do I need the optional ERV?

Choose optional ERV when the unit will provide the room’s fresh-air ventilation. Where the building already has a separate ventilation system, select the heating-and-cooling configuration.

How much ceiling space does the installation need?

The cabinet is 11-1/8 in. high. The ceiling layout also needs room for supports, ducts, drainage and access panels. Keep these allowances in the installation plan so the equipment stays hidden and remains accessible.

How is routine maintenance kept accessible?

Align a ceiling access panel with the service side of the unit. Leave enough space to remove filters and reach electrical components and the condensate drain, without blocking the opening with fixed finishes or other services.

What if gravity drainage is difficult to arrange?

Optional external condensate-pump interlock offers flexibility where a gravity drain is difficult to route. Keep the pump and drain accessible for cleaning and servicing.

Can different apartment layouts use different AURA models?

Yes. A development can combine different capacities and installation formats. Share the location, floor plans and dwelling mix so EXINDA can help compare models and provide the technical information for your project team.

Partner With EXINDA

Distributors & Dealers

Expand your HVAC offering with EXINDA heat pumps and ventilation systems, backed by product training and technical support.

Engineering Firms & Contractors

Get the performance data, submittals and engineering support you need to select equipment and move your project forward.

HVAC Brands

Bring your product ideas to market with EXINDA’s engineering, testing and manufacturing expertise.