EXINDA 1.5HP Ice Bath Chiller for Cold Plunge


HIGHER-CAPACITY COLD PLUNGE COOLING & HEATING

37°F / 3°CPublished minimum highlighted for US / EU selection
12,900Btu/h nominal cooling — North America

EXINDA 1.5HP Ice Bath Chiller integrates cooling, heating, circulation, filtration and ozone treatment in one compact hydronic unit.

105–132 gal / 400–500 LSuggested water volume
4.2 GPM / 16 L/minWater flow
110–120V or 220–240VNorth America / Europe
R3225 oz US / 0.71 kg EU
Request a quote or selection checkView technical data ↓

Choose the version for your market

  • North America: FBMDHC32B1V3U7U · 110–120 V / 1 Ph / 60 Hz
  • Europe: FBMDHC32B1V3U7 · 220–240 V / 1 Ph / 50 Hz

1.5HP Ice Bath Chiller Specifications

Choose the electrical and compliance configuration for the installation market. The North American and European versions share the same core cooling/heating platform but use different power supplies and published units.

Specification North America Europe
Model FBMDHC32B1V3U7U FBMDHC32B1V3U7
Cooling capacity 12,900 Btu/h 3,700 W
Heating capacity 18,425 Btu/h 5,200 W
Power supply 110–120 V / 1 Ph / 60 Hz 220–240 V / 1 Ph / 50 Hz
Rated input power 1,310 W 1,310 W
EER / COP 2.9 / 4.12 2.9 / 4.12
Water temperature range 37–104°F 2–40°C
Ambient operating range 36–109°F 2–43°C
Suggested water volume 105–132 gal 400–500 L
Water flow 4.2 GPM 16 L/min
Refrigerant R32 / 25 oz R32 / 0.71 kg
Water connections 1/2 in. thread 1/2 in. thread
Sound pressure 53 dB(A) @ 1 m 53 dB(A) @ 1 m
Net dimensions 25.9 × 18.1 × 23.2 in. 660 × 460 × 590 mm
Net weight 110 lb 50 kg
Maximum circuit breaker 15 A 15 A

Cooling & Heating Performance

The 1.5HP platform provides both cooling and heating. Published nominal capacity is 12,900 Btu/h cooling and 18,425 Btu/h heating for the North American version, and 3.7 kW cooling / 5.2 kW heating for the European version.

Reference cooling time — North America

Approximately 8 hours, based on 118 gal of water and a 64°F temperature reduction.

Reference cooling time — Europe

Approximately 8 hours, based on 500 L of water and an 18°C temperature reduction.

Selection note: Actual cooling time depends on water volume, starting and target temperatures, ambient conditions, tub insulation, cover use, plumbing configuration and surrounding heat gain.

Cooling, Heating and Water Treatment in One Unit

Cooling & Heating

One hydronic platform supports both cold-plunge cooling and water heating.

Built-In Circulation Pump

Integrated circulation simplifies the water circuit. The pump is not self-priming.

Three-Stage Water Treatment

Ozone generator, 20 μm micro filter and 40 μm washable filter.

Wi-Fi Available

Wi-Fi functionality is listed in both current model submittals.

Correct Installation for Reliable Water Circulation

  1. Position the chiller below the water line. Gravity helps feed water into the circulation pump.
  2. Connect the water lines correctly. Chiller outlet → tub inlet; tub outlet → chiller inlet.
  3. Prime before startup. Manually fill the filtration / water circuit before powering on.
  4. Remove trapped air. Keep the inlet hose submerged and free of air gaps or kinks. Repeat filling until water flow is steady.

Important: The built-in circulation pump is not self-priming.

What's Included

40 μm Washable Filter
1 pc
Water Pipe Adaptors
2 pcs
Camlock Adaptors
4 pcs
Teflon Tape
1 pc
Ball Valve
1 pc
Inlet & Outlet Water Pipes
2 pcs

Safety & Compliance

North American version

The current US submittal references conformity to UL 60335-1 and UL 60335-2-40, certification to CSA C22.2 No. 60335-1 and CSA C22.2 No. 60335-2-40, built-in GFCI protection and IPX4 water resistance.

European version

The current EU submittal shows CE, built-in RCD protection and IPX4 water resistance.

Confirm the applicable certification documentation for the exact model and destination market before specification.

1.5HP Ice Bath Chiller Technical Documents

North America — FBMDHC32B1V3U7U
Request the current US model-specific submittal.

Europe — FBMDHC32B1V3U7
Request the current EU model-specific submittal.

1.5HP Ice Bath Chiller Questions & Answers

How cold can the 1.5HP chiller get?

The North American submittal lists a 37–104°F water outlet range. The current European submittal lists 2–40°C; its feature summary states cooling down to 3°C.

What size cold plunge is suitable?

The published suggested volume is 105–132 gal for the North American version and 400–500 L for the European version.

Can it both cool and heat water?

Yes. Both current submittals identify the 1.5HP platform as hydronic cool and heat.

How long does it take to cool the water?

The published reference is approximately 8 hours under the stated test conditions: 118 gal with a 64°F reduction for the US version, or 500 L with an 18°C reduction for the EU version.

Does it include a circulation pump?

Yes. The pump is integrated, but it is not self-priming and the water circuit must be primed before startup.

Does it include water treatment?

Yes. The submittals list ozone treatment, a 20 μm micro filter and a 40 μm washable filter.

What is the difference between the US and EU versions?

The main published differences are model suffix, power supply, regional compliance references and the units used for performance data.