EXINDA Aura 12 000 Btu/h All-in-One-Wärmepumpe mit ERV (HPERV)


Comfort in every room. A cleaner building exterior.

Bring independent comfort to condos and apartments with heating, cooling and energy-recovery ventilation in one concealed ceiling unit. EXINDA AURA 12,000 Btu/h connects living areas and bedrooms through ductwork, while discreet exterior air openings keep individual outdoor condensers off the façade. The slim cabinet preserves usable floor space, with planned access for routine care.

12,000 Btu/h cooling14,000 Btu/h rated heating
Integrated ERVFresh-air ventilation with heat recovery
Ceiling-ducted installationDistributes air through the home
Individual controlWall controller included

Ceiling-Ducted HPERV Specifications

ModelICMPCGFF1AYE
System typeCeiling-ducted all-in-one heat pump ERV
Rated cooling capacity12,000 Btu/h at 95 °F DB / 75 °F WB outdoor and 80 °F DB / 67 °F WB indoor
Rated heating capacity14,000 Btu/h at 47 °F DB / 43 °F WB outdoor and 70 °F DB / 60 °F WB indoor
Low-temperature heating7,800 Btu/h at 17 °F; 7,165 Btu/h at 5 °F
ERV ventilation airflow42–135 CFM; 135 / 90 / 42 CFM high / medium / low
Indoor supply airflow400 CFM cooling / 430 CFM heating at 0.30 in. w.g.
Power supply208–240 V / 60 Hz / 1 Ph, hardwired
MCA / MOP20 A / 30 A, including electric heater basis
Maximum electric auxiliary heat3 kW
Maximum input power4,200 W
Compressor / refrigerantBLDC twin-rotary inverter / R32 A2L, 2.17 lb charge
Compressor operating range5 to 109 °F outdoor
Auxiliary heat operating range−31 to 109 °F outdoor
Sound pressure46 dB(A) at 1 m; 41 dB(A) at 3 m, ceiling installed, high heating airflow
Dimensions (W × D × H)46 × 45-11/16 × 11-1/8 in.
Installed weight205 lb
ControllerWall-mounted digital controller; optional Wi-Fi and BACnet
Certification

CSA APPROVED, AHRI IN PROGRAM

CSA certificate 80287910 · Canada and US · CSA product listing

HPERV Heating, Cooling and Ventilation Performance

Heat-pump capacity changes with outdoor temperature. The 650 CFM outdoor-air figure in the submittal belongs to the heat-pump outdoor air circuit; it is not the fresh-air ventilation delivery, which is 42–135 CFM.

Operating pointCapacity / airflowInput or COPTest condition
Cooling rating12,000 Btu/hEER 11.0 Btu/W95 °F DB / 75 °F WB outdoor; 80 °F DB / 67 °F WB indoor
Heating rating14,000 Btu/hCOP 2.4347 °F DB / 43 °F WB outdoor; 70 °F DB / 60 °F WB indoor
Low-temperature heating7,800 Btu/hCOP 1.8617 °F DB / 13 °F WB outdoor; 70 °F DB / 60 °F WB indoor
Minimum compressor condition7,165 Btu/hCOP 1.505 °F DB / 3 °F WB outdoor; 70 °F DB / 60 °F WB indoor
ERV-only heating test42 CFM ventilation27 W; 86% SRE / 90% adjusted SRE32 °F inlet supply
Indoor duct design400 CFM cooling / 430 CFM heating0.30 in. w.g. available external static pressure

AURA Technical Documents

Compare all AURA heat pump models

Related Reading

AURA Selection Questions

Can one unit serve living areas and bedrooms?

Yes. Supply ducts can branch to the living area and bedrooms, with a return-air path back to the unit. Plan the airflow for each room so the system serves the whole dwelling.

How do I choose between ceiling and floor-standing installation?

Choose ceiling installation when keeping the floor clear is a priority and there is space above the finished ceiling for the unit, ducts and service access. A vertical model is an alternative when ceiling depth is limited and a dedicated indoor equipment position is available.

Where should the equipment sit within the home?

A utility or laundry area can be a practical location, keeping the indoor compressor away from bedrooms and main seating areas. Coordinate vibration isolation, duct routes and a service opening before finishing the ceiling.

What needs to connect to the outside of the building?

Separate outdoor intake and discharge ducts connect the indoor unit to exterior air openings or a coordinated louver assembly. There is no separate outdoor condenser. Plan the openings, duct insulation and separation as part of the façade design.

How does the built-in ERV support fresh air and bathroom extraction?

The ERV brings in fresh air and extracts stale air while recovering energy. Bathroom extraction can be connected as part of the ventilation layout, with airflow and controls coordinated for the dwelling.

How much ceiling space does the installation need?

The cabinet is 11-1/8 in. high. The ceiling layout also needs room for supports, ducts, drainage and access panels. Keep these allowances in the installation plan so the equipment stays hidden and remains accessible.

How is routine maintenance kept accessible?

Align a ceiling access panel with the service side of the unit. Leave enough space to remove filters and reach electrical components and the condensate drain, without blocking the opening with fixed finishes or other services.

What if gravity drainage is difficult to arrange?

Optional external condensate-pump interlock offers flexibility where a gravity drain is difficult to route. Keep the pump and drain accessible for cleaning and servicing.

Can different apartment layouts use different AURA models?

Yes. A development can combine different capacities and installation formats. Share the location, floor plans and dwelling mix so EXINDA can help compare models and provide the technical information for your project team.

Mit EXINDA zusammenarbeiten

Globaler HLK-Hersteller und Anbieter kundenspezifischer HLK-Lösungen

EXINDA ist ein globaler HLK-Hersteller, der auf Wärmepumpen, Lüftungssysteme und kundenspezifische Klimalösungen für Wohn- und Gewerbeanwendungen spezialisiert ist.

Wir arbeiten weltweit mit Vertriebspartnern, Ingenieuren, Installationsunternehmen und OEM-Partnern zusammen.

1. HLK-Vertriebspartner und Fachhändler

Wir unterstützen Partner weltweit mit zuverlässigen Wärmepumpen- und Lüftungslösungen.

2. Ingenieur- und Installationsunternehmen
Wir bieten technische Dokumentation, Unterstützung bei der Produktauswahl und Projektbetreuung.

3. Bauunternehmen und Bauherren
Wir liefern energieeffiziente HLK-Lösungen für Wohnanlagen, Hotels, Gesundheitseinrichtungen, Schulen, Büros und Gewerbeprojekte.