all-in-one heat pump

Ceiling-Ducted vs Wall-Mounted All-in-One Heat Pumps: Which Fits Your Building?

Ceiling-Ducted vs Wall-Mounted All-in-One Heat Pumps: Which Fits Your Building?

Both types put the whole heat pump inside the apartment and only need two holes in the exterior wall. That is where the similarity ends. Here is how they differ and when each one makes sense.

Wall-mounted all-in-one

The unit hangs on an exterior wall, low or high, with the intake and exhaust grilles directly behind it. Air is conditioned and blown straight into the room it sits in.

  • One unit, one room. A two-bedroom needs three units.
  • Fastest install. No ductwork, a few hours per unit.
  • Fresh air is optional and usually a separate module.
  • The unit is visible, and the wall behind it has to face outside.
  • Noise is in the room with the tenant.

Good for studios, retrofits where nothing above the ceiling can be touched, and buildings where every room has an exterior wall.

Ceiling-ducted all-in-one with ERV

The unit sits above a suspended ceiling or in a bulkhead, usually near the exterior wall. Supply ducts run to each room, return comes back through a grille, and an ERV core inside the cabinet brings in filtered outside air and exhausts the bathroom.

  • One unit for the suite. A studio or one-bedroom runs on a single 12,000 Btu/h unit; larger suites use two or a higher-capacity model.
  • Fresh air can be part of the machine. Ducted units from Innova and EXINDA have the ERV core inside the cabinet, so continuous outdoor air is covered without a second product. Check this per model; it is not true of every ducted unit.
  • Nothing on the wall. Only diffusers and a return grille are visible.
  • Noise stays above the ceiling. The EXINDA HPERV measures 48 dB(A) at 1 m through gypsum board.
  • Needs ceiling depth (the HPERV is 11-1/8 in tall) and a service opening.
  • Static pressure matters. Check that the unit's rated external static covers your duct run. The HPERV supplies 430 CFM at 0.30 in. w.g., which is roughly 39 ft of equivalent duct.

Good for new high-rise and mid-rise apartments, window-wall buildings, and any project where the mechanical engineer has to show a fresh-air path.

Quick decision checklist

  1. Does the code require mechanical fresh air to each suite? If yes, go ducted with a built-in ERV, or budget a separate ERV with a wall unit.
  2. Is there 12 in or more above the ceiling near the exterior wall? If no, wall-mounted.
  3. How many rooms per suite? One room, either works. Two or more, ducted is cheaper per suite once you count units and wall openings.
  4. Will the tenant see and hear it? If that matters to the developer, ducted.
  5. Cold climate? Compare heating capacity at 5°F and 17°F, and confirm the backup heater size. Do this for either type.

Where to go from here

Have a project to size? Send suite count, project location, design requirements and a typical unit plan to info@exindagroup.com and ask for project selection support.

Puede que te interese

Exinda Announces Strategic Partnership with CENTRO-GAS in Serbia

Colabore con EXINDA

Fabricante global de climatización y proveedor de soluciones personalizadas

EXINDA es un fabricante global de climatización especializado en bombas de calor, sistemas de ventilación y soluciones climáticas personalizadas para aplicaciones residenciales y comerciales.

Colaboramos con distribuidores, ingenieros, contratistas y socios OEM de todo el mundo.

1. Distribuidores y comerciantes de climatización
Apoyamos a nuestros socios de todo el mundo con soluciones fiables de bombas de calor y ventilación.

2. Empresas de ingeniería y contratistas
Proporcionamos documentación técnica, asistencia para la selección de productos y apoyo a proyectos.

3. Socios OEM / ODM
Ofrecemos soluciones de climatización personalizadas, fabricación con marca privada y apoyo al desarrollo de productos.