Complete indoor comfort. More freedom for building design.

AURA All-in-One Heat Pump ERV Systems

EXINDA AURA brings heating, cooling and fresh-air options together without a separate outdoor condenser for every home — the equipment multifamily specifications describe as a packaged terminal heat pump (PTHP) with integrated ERV. Ductwork carries comfort to living areas and bedrooms, while discreet exterior air openings keep the building façade uncluttered. Choose ceiling or floor-standing installation to suit the layout, with individual comfort control and practical access for maintenance.

North American Models

AURA for North America

Plan individual heating, cooling and fresh-air options for condos, multifamily developments, hospitality projects and modular or detached single-family homes. Compare North American models from smaller suites to larger multi-bedroom layouts.

Europe, Australia & New Zealand

AURA for Europe, Australia & New Zealand

Comfort that fits the home: concealed systems for flats, compact houses and hotel rooms, or accessible floor-standing units for larger apartments and townhouses. Compare the 50 Hz range for Europe, Australia and New Zealand by capacity and installation layout.

Heating, cooling and fresh air

Choose integrated HPERV when each home needs all three functions. The ceiling-suspended heat pump offers optional ERV for projects with different ventilation arrangements.

The energy-recovery section of the HPERV is the same enthalpy core as the Breeze 42–170 CFM ERV (ICMBCOFF1AYS, HVI ID 2005500): 86% sensible recovery efficiency at 42 CFM at 0 °C and 67% at −25 °C, with no electric preheater. Use that HVI record for the ventilation side of an energy model.

Ceiling or vertical installation

Concealed ceiling models free up floor space in compact apartments, modular homes and hotel rooms. Plan accessible service openings and choose optional external condensate-pump interlock where needed. The 18,000 and 25,000 Btu/h vertical models serve larger homes with two or more bedrooms, with standing-height service access and optional 3, 4 or 5 kW electric heating.

Match the project configuration

Select the regional model, then let your HVAC designer match its capacity and electrical requirements to the home.

Technical support

Project documents and coordination support

Find model-specific data and drawings on each product page, or discuss the project with our team.

Questions & answers

AURA Selection Questions

Does every AURA model include fresh-air ventilation?

HPERV models combine heating, cooling and energy-recovery ventilation. The ceiling-suspended heat pump offers ERV as an option, so you can choose it to suit the project’s ventilation plan.

Does each apartment need an outdoor condenser?

No separate outdoor condenser is required. Each unit connects to outdoor intake and exhaust openings, helping keep balconies and exterior equipment areas clear.

Which AURA models suit larger homes with two or more bedrooms?

Consider the 18,000 or 25,000 Btu/h vertical models. They offer higher capacity for larger living spaces, ducted air distribution and convenient standing-height maintenance access. Both offer optional 3, 4 or 5 kW electric auxiliary heating.

Can I use different AURA models within one development?

Yes. Different dwelling layouts may need different capacities or cabinet formats. Share the floor plans and unit mix so the design team can compare the appropriate models.

Where is the ERV efficiency data for the HPERV?

On the HVI record of its energy-recovery section, model ICMBCOFF1AYS, HVI ID 2005500: 86% sensible recovery efficiency at 42 CFM at 0 °C and 67% at −25 °C, tested to CSA C439. The heat pump side is rated separately at AHRI conditions; both sets of figures are in the HPERV submittal on the product page. Quote the model number with the HVI ID when the project requires certified ventilation data.

Can AURA be used in a detached or modular single-family home?

Yes. A low-load home built to a passive-house standard is served by one unit: the 8,500 Btu/h ceiling-suspended model with the ERV option for smaller plans, or the 12,000 Btu/h ceiling-ducted HPERV where one unit carries the whole home and its ventilation. Modular builders can fit the unit, ducts and the two exterior openings in the factory. Send the plan, location and ventilation rate for a selection; this is an application example rather than a published project reference. The figures an energy modeler asks for are listed in Aura HPERV for PHIUS multifamily and modular homes.

Partner With EXINDA

Distributors & Dealers

Expand your HVAC offering with EXINDA heat pumps and ventilation systems, backed by product training and technical support.

Engineering Firms & Contractors

Get the performance data, submittals and engineering support you need to select equipment and move your project forward.

HVAC Brands

Bring your product ideas to market with EXINDA’s engineering, testing and manufacturing expertise.