EXINDA 100CFM Energy Recovery Ventilator | Ultra-Slim Decentralized ERV ICMBCNF1AYE


Engineered for the constraints of North American multi-family retrofits, the EXINDA 100CFM solves the "low-clearance" challenge in concrete slab and restricted plenum projects. This unit provides a streamlined, decentralized approach to ASHRAE 62.2 compliance, eliminating the need for complex, building-wide duct distribution.

Key Performance Highlights

  • Space-Saving Footprint: 9-1/12" profile and 36 lb weight allow for effortless installation in tight ceiling cavities with minimal structural interference.

  • Auto-Balancing Smartflow™: Integrated ECM technology delivers consistent airflow up to 1.2 in. w.g. ESP, significantly reducing on-site commissioning and balancing labor.

  • Cold Climate Certified: Advanced defrost logic ensures reliable operation down to -25°C (-13°F) without requiring external electric pre-heaters, optimizing overall energy efficiency.

  • Streamlined Integration: Universal 24V thermostat interlock (C, G, R, W, Y) ensures rapid, field-proven connectivity with existing AHUs and furnaces.

  • Decentralized IAQ: Isolates ventilation per unit to eliminate cross-contamination and the common balancing issues associated with centralized exhaust/supply shafts.

Technical Compliance

  • Standards: ASHRAE 62.2 compliant.

  • Certification: UL1812 safety listed; CSA C439, HVI, Energy Star performance verified.

  • Acoustics: Low-noise operation (30 dBA @ 1m), engineered to exceed tenant comfort expectations.

1. Product Overview

Engineering Specification Criteria Certified Parameter
Equipment Category Energy Recovery Ventilator (ERV)
Factory Model Number ICMBCNF1AYE (Exinda 100CFM Series)
Project Application Suitability Residential / Multi-family / High-density Retrofit
Mounting Configuration Ceiling Mounted / Slim-profile Horizontal Concealed Deployment
Core Control Architecture Constant Airflow Architecture + Intelligent Auto-Balancing Technology

2. Mechanical Performance & Energy Metrics

Performance Index / Selection Metrics Verified Value & Test Standards
Airflow Capacity Range 53 – 100 CFM (Selectable airflow speed range for multi-family compliance)
Rated Operational Airflow 100 CFM @ 0.4 in. w.g. (Static Pressure Engineering Baseline)
Blower Fan Speed Configuration 3-Speed Control Operation (Low / Mid / High Speed Curves)
Maximum External Static Pressure Sustains stable continuous operation up to 1.2 in. w.g. (300 Pa)
Energy Exchanger Core Type Cross-flow polymer core (Simultaneous sensible and latent energy recovery)
Sensible Recovery Efficiency (SRE) 77% SRE at 64 scfm / 73% SRE at 92 scfm (Verified at 0°C / 32°F)
Adjusted Sensible Recovery (ASRE) 80% ASRE at 64 scfm / 77% ASRE at 92 scfm (Verified at 0°C / 32°F)
Cooling Mode Total Recovery Efficiency 63% Sensible total efficiency / 65% Adjusted total recovery efficiency
Net Moisture Transfer Rate Up to 34% latent moisture transfer at 65 scfm (At 95°F / 35°C inlet supply)
Extreme Cold Operational Stability Limit Stable continuous performance sustained down to -25°C (-13°F) ambient
Labor Cost & Setup Time Mitigation Auto-balancing & self-adjusting features save up to 20 minutes per unit
Up to 77% SRE Certified

High-Efficiency Climate Optimization

Engineered to comply fully with the rigorous CSA 439 standard. This system delivers an exceptional 77% Sensible Recovery Efficiency (SRE) at 64 scfm, drastically lowering the active electrical heating and cooling loads on North American building envelopes while sustaining balanced fresh airflow.

Severe Cold Adaptability

Built for Extreme Northern Climates

Specially optimized for Canadian and Northern US building codes. Unlike standard ventilation products that suffer from core freeze or performance degradation, Exinda’s decentralized architecture is performance-verified to maintain continuous operational stability even under brutal -25°C (-13°F) winter ambient conditions.

Acoustic Comfort

Ultra-Quiet 30 dBA Multi-Family Profile

A consultant engineer's premier choice for strict localized acoustic specification matching. Fully validated inside professional sound laboratories to sustain a whisper-quiet 30 dBA sound pressure level at 1 meter during high-speed operation, ensuring total multi-family tenant comfort and privacy.

4. Advanced System Integration & Operational Logic

Engineering System & Integration Parameters Detailed Operational Logic & Performance Evidence (Ground Truth)
Defrost Control & Severe Cold Climate Protection The system incorporates an automated exhaust defrost cycle control mechanism engineered to sustain continuous performance efficiency and core integrity under winter ambient operational limits down to -25°C (-13°F) without thermal failure.
Centralized HVAC Interlock & Thermostat Wiring Features an integrated 24V universal thermostat terminal strip supporting standard C, G, R, W, and Y connections, allowing seamless interlock integration directly into a centralized furnace or Air Handling Unit (AHU) low-voltage terminal block.
Constant Airflow & Installer Labor Cost Optimization Utilizes advanced constant airflow regulation architecture backed by innovative auto-balancing and self-adjusting technology, ensuring perfectly balanced residential ventilation across external static pressures up to 1.2 in. w.g. while reducing contractor field setup time by up to 20 minutes per unit.
Blower Fan Calibration & Static Pressure Delivery Equipped with a high-performance digitally controlled brushless ECM motor assembly, delivering a rated operational baseline of 90 CFM at a 0.4 in. w.g. engineering static pressure threshold, with a total selectable operational range spanning 53 to 100 CFM.
Energy Recovery Core Technology & Latent Transfer Employs a premium cross-flow non-washable engineering polymer energy recovery core, verified to simultaneously pre-condition incoming fresh air by capturing sensible heat efficiency up to 77% and transferring up to 34% latent summer moisture load.
Chassis Profile, Spatial Footprint & Single-Installer Setup Constructed in a lightweight 36 lbs configuration with an ultra-slim physical profile measuring 9-1/12" (H) x 20-1/16" (W) x 20-1/14" (D), optimized for tight decentralized ceiling-mounted concealment, utilizing standard 4-inch round ducted connection collars for effortless physical deployment.
Low-Voltage Auxiliary Controller Infrastructure Designed with dedicated internal terminal connections optimized for 3-wire 20 Gauge (Minimum) low-voltage field wiring, allowing quick-snap connection to localized auxiliary hardware such as bathroom ventilation override timers.

Target Applications & Structural Constraints

  • Ceiling Height & Plenum Constraints: With an ultra-slim profile of only 9-1/12 inches, this unit resolves spatial bottlenecks in high-rise apartments, concrete slab multi-family buildings, and low-ceiling retrofits.
  • Decentralized IAQ Management: Eliminates the cross-contamination risks and balancing complexities of centralized shafts by zoning indoor air quality (IAQ) per individual apartment unit.
  • Static Pressure Stability: The Smartflow™ micro-processor automatically adjusts motor EC speed to compensate for external static pressure (ESP) fluctuations caused by wind or duct bends.

Frequently Asked Questions (Engineering & Procurement)

Q1: Can the EXINDA 100CFM ERV be used as a direct alternative to Panasonic FV-10VEC2?

Yes. The EXINDA ICMBCNF1AYE provides equivalent 40-100 CFM adjustable airflow and continuous balanced ventilation, utilizing an ultra-slim 9.08-inch profile specifically designed to fit tighter ceiling joists than standard Panasonic units.

Q2: Does this unit comply with ASHRAE 62.2 standards for multifamily buildings?

Absolutely. The 100 CFM capacity and localized continuous operation parameters are fully engineered to satisfy ASHRAE 62.2 indoor air quality metrics for modern multi-family residential projects.

Q3: How does the auto-defrost protection operate in cold climates?

When outdoor temperatures drop below -5°C (23°F) down to -25°C (-13°F), the internal controller initiates a periodic recirculation/defrost cycle to prevent frost buildup on the energy exchange core without requiring energy-intensive electric pre-heaters.

3 production lines
40000+ annual output

Heat recovery ventilator manufacturer

Exinda manufacturing HR and ERV ventilator products with more than 15 years experience.

We have wide range of residential and commercial ventilation products from 50CFM up to 2000CFM. Our ventilator are CSA approved for North America market.

We are looking for distributor, Welcome to contact us for more details