EXINDA Breeze 54-100 CFM Energy Recovery Ventilator


WALL-MOUNTED RESIDENTIAL ENERGY RECOVERY VENTILATION

EXINDA Breeze IWMBCOOF1AYE is a vertical wall-mounted residential ERV that keeps the floor clear and needs no ceiling cavity, with four 4 in. ducts leaving the top of the cabinet. It has three standard settings of 54, 70 and 100 CFM with automatic balancing, holds the selected airflow as duct resistance rises, and can be interlocked with a furnace or air handler through 24 V thermostat terminals.

16-5/8 in. of wallVertical cabinet, no floor or ceiling space
54 / 70 / 100 CFMStandard low / medium / high settings
102 CFM at 0.4 in. w.g.HVI certified net supply
120 V / 60 Hz / 1 PhElectrical supply

Is this the right wall-mounted ERV for your project?

  • Floor area or ceiling depth is the constraint, and wall space is available.
  • The wall can carry the 44 lb cabinet plus duct loads.
  • Required continuous ventilation is within the certified 102 CFM envelope.
  • There is bend radius above the cabinet for four 4 in. ducts.

Before confirming the model, verify wall structure, top clearance for duct bends, net airflow at design static pressure and front service access.

Breeze ERV Specifications

ModelIWMBCOOF1AYE
Product typeVertical wall-mounted residential ERV
Standard airflow settings54 / 70 / 100 CFM at 0.1 / 0.2 / 0.4 in. w.g.
Certified net supply at 0.4 in. w.g. (HVI)102 CFM
Sensible recovery efficiency (HVI)72% at 66 CFM net airflow, 36 W
Wall footprint (W × D)16-5/8 × 16-9/16 in.
Dimensions (H × W × D)20-5/8 × 16-5/8 × 16-9/16 in.
Power supply120 V / 60 Hz / 1 Ph
Duct connection4 in., top of cabinet
Control interfaceWall controller; 24 V thermostat terminals (C / G / R / W / Y) for furnace or air-handler interlock; optional timer and dehumidistat inputs
MCA / MOP1.4 A / 15 A
Maximum input power180 W
Sound pressure, HH / H / L30 / 27 / 23 dB(A) — per submittal; measurement distance not stated.
Outdoor operating range−18 to 109 °F DB
Filters2 × washable MERV 8
Energy-recovery coreCross-flow, non-washable
BalancingAutomatic balancing
DefrostRecirculation defrost
Net weight44 lb
Certification referencesHVI ID 2005360; CSA certificate 80227354 (UL 1812 safety, CSA C439 performance)

Airflow and Energy Recovery Performance

Fan curve values show how the high airflow point responds to external static pressure. Energy recovery performance is reported at separate test conditions, each with its own inlet temperature, airflow and power.

PerformanceNet airflowPowerRecovery metric
0.1 in. w.g. fan curve98 CFM69 W—
0.4 in. w.g. fan curve102 CFM95 W—
0.8 in. w.g. fan curve104 CFM125 W—
32 °F inlet supply66 CFM36 W72% SRE / 76% adjusted SRE
32 °F inlet supply102 CFM74 W67% SRE / 72% adjusted SRE
95 °F inlet supply57 CFM33 W57% total / 59% adjusted total recovery

Breeze ERV Technical Documents

Read the Breeze 54–100 CFM ERV technical brief for applications and installation planning.

Compare all Breeze residential ERV models

Breeze ERV Selection Questions

When is a wall-mounted ERV the better choice?

The cabinet stands vertically and occupies 16-5/8 by 16-9/16 in. of wall, so it keeps the mechanical room floor clear and needs no ceiling cavity at all. Choose it when floor area or ceiling depth is the constraint and there is a structural wall able to carry 44 lb plus duct loads.

Is the 100 CFM setting available at design static pressure?

Yes, with margin. The high setting is 100 CFM and the fan curve reports 98 CFM net supply at 0.1 in. w.g., 102 CFM at 0.4 and 104 CFM at 0.8. The ECM motor holds the selected airflow as duct resistance rises, so schedule against the calculated external static pressure rather than a nominal figure.

Can it run with a furnace or air handler rather than as a standalone unit?

Yes. The controller wires to 24 V thermostat terminals (C / G / R / W / Y) and to a furnace 24 V terminal block, so ventilation can follow the HVAC system rather than run on its own schedule. A bathroom timer with 20 / 40 / 60 minute high-speed cycles and an electronic dehumidistat are supported as optional inputs.

What has to be left clear around the unit?

Four 4 in. ducts leave the top of the cabinet, so allow bend radius above it, and keep the front clear for filter and core service and for controller wiring. Confirm the dimension drawing and local electrical clearances before coordination.

Collaborez avec EXINDA

Fabricant mondial d’équipements CVC et fournisseur de solutions sur mesure

EXINDA est un fabricant mondial d’équipements CVC spécialisé dans les pompes à chaleur, les systèmes de ventilation et les solutions climatiques sur mesure pour les applications résidentielles et tertiaires.

Nous collaborons avec des distributeurs, des ingénieurs, des installateurs et des partenaires OEM dans le monde entier.

1. Distributeurs et revendeurs CVC

Nous accompagnons nos partenaires dans le monde entier avec des solutions fiables de pompes à chaleur et de ventilation.

2. Bureaux d’études et installateurs
Nous fournissons la documentation technique, une aide à la sélection des produits et un accompagnement des projets.

3. Entreprises de construction et maîtres d’ouvrage
Nous fournissons des solutions CVC économes en énergie pour les ensembles résidentiels, les hôtels, les établissements de santé, les écoles, les bureaux et les projets tertiaires.