{"product_id":"exinda-ceiling-mounted-louvered-water-cooled-package-unit","title":"EXINDA Ceiling-Mounted Louvered Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eCeiling-Mounted Louvered Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,000–8,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\n\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\n\u003cp\u003eA ceiling-mounted package with louvered discharge for direct, adjustable supply-air delivery in industrial buildings where floor space is limited.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19DB\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤62 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-28DB\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e190 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-38DB\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1360×850×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e260 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-56DB\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e8,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤67 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e2160×950×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e400 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow the system works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\n\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\n\u003ch2\u003eSelection guidance\u003c\/h2\u003e\n\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, external static pressure, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\n\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\n\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19DB","offer_id":56412439216433,"sku":"XDZFL-19DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-28DB","offer_id":56412439249201,"sku":"XDZFL-28DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-38DB","offer_id":56412439281969,"sku":"XDZFL-38DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-56DB","offer_id":56412439314737,"sku":"XDZFL-56DB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19db-correct-logo-v3.jpg?v=1790068363","url":"https:\/\/exindagroup.com\/it\/products\/exinda-ceiling-mounted-louvered-water-cooled-package-unit","provider":"EXINDA","version":"1.0","type":"link"}