EXINDA 1.5HP Ice Bath Chiller for Cold Plunge
HIGHER-CAPACITY COLD PLUNGE COOLING & HEATING
EXINDA 1.5HP Ice Bath Chiller integrates cooling, heating, circulation, filtration and ozone treatment in one compact hydronic unit.
Choose the version for your market
- North America: FBMDHC32B1V3U7U · 110–120 V / 1 Ph / 60 Hz
- Europe: FBMDHC32B1V3U7 · 220–240 V / 1 Ph / 50 Hz
1.5HP Ice Bath Chiller Specifications
Choose the electrical and compliance configuration for the installation market. The North American and European versions share the same core cooling/heating platform but use different power supplies and published units.
| Specification | North America | Europe |
|---|---|---|
| Model | FBMDHC32B1V3U7U | FBMDHC32B1V3U7 |
| Cooling capacity | 12,900 Btu/h | 3,700 W |
| Heating capacity | 18,425 Btu/h | 5,200 W |
| Power supply | 110–120 V / 1 Ph / 60 Hz | 220–240 V / 1 Ph / 50 Hz |
| Rated input power | 1,310 W | 1,310 W |
| EER / COP | 2.9 / 4.12 | 2.9 / 4.12 |
| Water temperature range | 37–104°F | 2–40°C |
| Ambient operating range | 36–109°F | 2–43°C |
| Suggested water volume | 105–132 gal | 400–500 L |
| Water flow | 4.2 GPM | 16 L/min |
| Refrigerant | R32 / 25 oz | R32 / 0.71 kg |
| Water connections | 1/2 in. thread | 1/2 in. thread |
| Sound pressure | 53 dB(A) @ 1 m | 53 dB(A) @ 1 m |
| Net dimensions | 25.9 × 18.1 × 23.2 in. | 660 × 460 × 590 mm |
| Net weight | 110 lb | 50 kg |
| Maximum circuit breaker | 15 A | 15 A |
Cooling & Heating Performance
The 1.5HP platform provides both cooling and heating. Published nominal capacity is 12,900 Btu/h cooling and 18,425 Btu/h heating for the North American version, and 3.7 kW cooling / 5.2 kW heating for the European version.
Reference cooling time — North America
Approximately 8 hours, based on 118 gal of water and a 64°F temperature reduction.
Reference cooling time — Europe
Approximately 8 hours, based on 500 L of water and an 18°C temperature reduction.
Selection note: Actual cooling time depends on water volume, starting and target temperatures, ambient conditions, tub insulation, cover use, plumbing configuration and surrounding heat gain.
Cooling, Heating and Water Treatment in One Unit
Cooling & Heating
One hydronic platform supports both cold-plunge cooling and water heating.
Built-In Circulation Pump
Integrated circulation simplifies the water circuit. The pump is not self-priming.
Three-Stage Water Treatment
Ozone generator, 20 μm micro filter and 40 μm washable filter.
Wi-Fi Available
Wi-Fi functionality is listed in both current model submittals.
Correct Installation for Reliable Water Circulation
- Position the chiller below the water line. Gravity helps feed water into the circulation pump.
- Connect the water lines correctly. Chiller outlet → tub inlet; tub outlet → chiller inlet.
- Prime before startup. Manually fill the filtration / water circuit before powering on.
- Remove trapped air. Keep the inlet hose submerged and free of air gaps or kinks. Repeat filling until water flow is steady.
Important: The built-in circulation pump is not self-priming.
What's Included
1 pc
2 pcs
4 pcs
1 pc
1 pc
2 pcs
Safety & Compliance
North American version
The current US submittal references conformity to UL 60335-1 and UL 60335-2-40, certification to CSA C22.2 No. 60335-1 and CSA C22.2 No. 60335-2-40, built-in GFCI protection and IPX4 water resistance.
European version
The current EU submittal shows CE, built-in RCD protection and IPX4 water resistance.
Confirm the applicable certification documentation for the exact model and destination market before specification.
1.5HP Ice Bath Chiller Technical Documents
North America — FBMDHC32B1V3U7U
Request the current US model-specific submittal.
Europe — FBMDHC32B1V3U7
Request the current EU model-specific submittal.
1.5HP Ice Bath Chiller Questions & Answers
How cold can the 1.5HP chiller get?
The North American submittal lists a 37–104°F water outlet range. The current European submittal lists 2–40°C; its feature summary states cooling down to 3°C.
What size cold plunge is suitable?
The published suggested volume is 105–132 gal for the North American version and 400–500 L for the European version.
Can it both cool and heat water?
Yes. Both current submittals identify the 1.5HP platform as hydronic cool and heat.
How long does it take to cool the water?
The published reference is approximately 8 hours under the stated test conditions: 118 gal with a 64°F reduction for the US version, or 500 L with an 18°C reduction for the EU version.
Does it include a circulation pump?
Yes. The pump is integrated, but it is not self-priming and the water circuit must be primed before startup.
Does it include water treatment?
Yes. The submittals list ozone treatment, a 20 μm micro filter and a 40 μm washable filter.
What is the difference between the US and EU versions?
The main published differences are model suffix, power supply, regional compliance references and the units used for performance data.
1.5HP Ice Bath Chiller
Request Selection Support
Send us your country, tub volume, starting water temperature, target temperature, ambient conditions and expected quantity. EXINDA can help confirm the correct US or EU configuration.