{"title":"Industrial Water-Cooled Packaged Air Conditioners","description":"\u003cp\u003e\u003cstrong\u003eIndustrial water-cooled DX package units with remote adiabatic fluid cooling for factories, workshops, warehouses and other large indoor spaces.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEXINDA Water-Cooled Package Units (WCPU) integrate the compressor, DX evaporator, water-cooled condenser, supply fan and controls in the indoor package. Condenser-water piping connects each unit to a remote adiabatic fluid cooler or a suitable central cooling-water system, keeping the outdoor heat-rejection air stream separate from the conditioned indoor air.\u003c\/p\u003e\n\u003ch2\u003eChoose the right air-distribution format\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-floor-standing-louvered-water-cooled-package-unit\"\u003e\u003cstrong\u003eFloor-standing louvered (LB)\u003c\/strong\u003e\u003c\/a\u003e — adjustable direct discharge for open industrial areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-floor-standing-long-throw-jet-water-cooled-package-unit\"\u003e\u003cstrong\u003eFloor-standing long-throw jet (LS)\u003c\/strong\u003e\u003c\/a\u003e — direct long-range air delivery without supply ductwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-floor-standing-ducted-water-cooled-package-unit\"\u003e\u003cstrong\u003eFloor-standing ducted (LF)\u003c\/strong\u003e\u003c\/a\u003e — project-specific ducted air distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-ceiling-suspended-ducted-water-cooled-package-unit\"\u003e\u003cstrong\u003eCeiling-suspended ducted (DF)\u003c\/strong\u003e\u003c\/a\u003e — concealed ducted delivery while keeping floor space clear.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-ceiling-suspended-long-throw-jet-water-cooled-package-unit\"\u003e\u003cstrong\u003eCeiling-suspended long-throw jet (DS)\u003c\/strong\u003e\u003c\/a\u003e — overhead direct air delivery for large spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/it\/products\/exinda-ceiling-mounted-louvered-water-cooled-package-unit\"\u003e\u003cstrong\u003eCeiling-mounted louvered (DB)\u003c\/strong\u003e\u003c\/a\u003e — adjustable overhead discharge for industrial interiors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct range\u003c\/h2\u003e\n\u003cp\u003eSix indoor air-distribution formats are available, each with 19.5, 28, 38 and 56 kW nominal cooling capacities. Depending on the series, maximum airflow ranges from 5,000 to 12,000 m³\/h. Listed models use R410A, 380 V \/ 3 N~ \/ 50 Hz power, IPX4 protection and Class I construction.\u003c\/p\u003e\n\u003ch2\u003eHow to select a system\u003c\/h2\u003e\n\u003cp\u003eStart with the project cooling-load calculation, required airflow and preferred air-distribution method. Then confirm entering condenser-water temperature, available water flow and pressure, sound target, structural conditions, drainage, service access and control requirements. Final selection should not be based on floor area alone.\u003c\/p\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor process and assembly areas\u003c\/li\u003e\n\u003cli\u003eIndustrial buildings requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eAre these direct evaporative coolers?\u003c\/h3\u003e\u003cp\u003eNo. These are water-cooled DX package units. The indoor DX evaporator cools and dehumidifies the recirculated air, while a condenser-water loop transfers heat to the outdoor heat-rejection system.\u003c\/p\u003e\n\u003ch3\u003eCan the units use a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, when the system water temperatures, flow, pressure and water quality meet the project requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich indoor format should I choose?\u003c\/h3\u003e\u003cp\u003eUse louvered units for adjustable direct discharge, jet units for long-throw direct delivery and ducted units for routed or targeted air distribution. Choose floor-standing or ceiling-suspended installation according to available space and structural conditions.\u003c\/p\u003e\n\u003ch3\u003eWhat information is needed for selection?\u003c\/h3\u003e\u003cp\u003eProvide the cooling load, indoor and outdoor design conditions, building layout, required airflow, sound target, available electrical supply and condenser-water conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlanning an industrial cooling project?\u003c\/strong\u003e Send EXINDA your project schedule and design conditions for model selection support.\u003c\/p\u003e","products":[{"product_id":"exinda-floor-standing-louvered-water-cooled-package-unit","title":"EXINDA Floor-Standing Louvered Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eFloor-Standing Louvered Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,000–8,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\u003cp\u003eA floor-standing indoor package with adjustable louvered discharge for direct supply-air distribution. It is suited to open industrial areas that need straightforward installation and local airflow adjustment.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19LB\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e3.98 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤62 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e780×540×1800\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e160 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-28LB\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.16 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e780×540×1800\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e180 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-38LB\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.61 kW\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e7,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e780×540×2000\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e210 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-56LB\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.16 kW\u003c\/td\u003e\n\u003ctd\u003e24.5 A\u003c\/td\u003e\n\u003ctd\u003e8,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤68 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e1260×768×1960\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e320 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\u003ch2\u003eHow the system works\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\u003ch2\u003eSelection guidance\u003c\/h2\u003e\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19LB","offer_id":56290212643121,"sku":"XDZFL-19LB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-28LB","offer_id":56412472213809,"sku":"XDZFL-28LB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-38LB","offer_id":56412472246577,"sku":"XDZFL-38LB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-56LB","offer_id":56412472279345,"sku":"XDZFL-56LB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19lb-correct-logo-v3.jpg?v=1790068302"},{"product_id":"exinda-floor-standing-long-throw-jet-water-cooled-package-unit","title":"EXINDA Floor-Standing Long-Throw Jet Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eFloor-Standing Long-Throw Jet Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,500–12,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\u003cp\u003eA floor-standing indoor package with long-throw jet outlets for direct air delivery across large industrial spaces where ductwork is not preferred.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19LS\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e780×720×2000\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-28LS\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e780×720×2000\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e188 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-38LS\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤68 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1260×768×1960\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e220 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-56LS\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e12,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤69 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e1260×768×1960\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e330 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\u003ch2\u003eHow the system works\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\u003ch2\u003eSelection guidance\u003c\/h2\u003e\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19LS","offer_id":56308114161969,"sku":"XDZFL-19LS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-28LS","offer_id":56412490563889,"sku":"XDZFLB-28LS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-38LS","offer_id":56412490596657,"sku":"XDZFLB-38LS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-56LS","offer_id":56412490629425,"sku":"XDZFLB-56LS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19ls-correct-logo-v3.jpg?v=1790068326"},{"product_id":"exinda-floor-standing-ducted-water-cooled-package-unit","title":"EXINDA Floor-Standing Ducted Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eFloor-Standing Ducted Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,500–12,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\u003cp\u003eA floor-standing indoor package for ducted air distribution, allowing project-specific supply routing and targeted delivery across large industrial interiors.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19LF\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤62 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e780×580×1450\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-28LF\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e780×580×1450\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e188 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-38LF\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1260×768×2010\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e220 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-56LF\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e12,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤67 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e1260×768×2120\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e400 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\u003ch2\u003eHow the system works\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\u003ch2\u003eSelection guidance\u003c\/h2\u003e\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19LF","offer_id":56401954013489,"sku":"XDZFL-19LF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-28LF","offer_id":56412490662193,"sku":"XDZFLB-28LF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-38LF","offer_id":56412490694961,"sku":"XDZFLB-38LF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-56LF","offer_id":56412490727729,"sku":"XDZFLB-56LF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19lf-correct-logo-v3.jpg?v=1790068354"},{"product_id":"exinda-ceiling-suspended-ducted-water-cooled-package-unit","title":"EXINDA Ceiling-Suspended Ducted Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eCeiling-Suspended Ducted Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,500–12,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\n\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\n\u003cp\u003eA concealed ceiling-suspended indoor package for ducted air distribution. It supports project-specific supply layouts where floor space must remain clear.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19DF\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤62 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-28DF\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e190 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-38DF\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1360×850×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e260 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-56DF\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e12,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤67 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e2160×950×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e400 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow the system works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\n\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\n\u003ch2\u003eSelection guidance\u003c\/h2\u003e\n\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, external static pressure, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\n\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\n\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19DF","offer_id":56412438921521,"sku":"XDZFL-19DF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-28DF","offer_id":56412438954289,"sku":"XDZFL-28DF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-38DF","offer_id":56412438987057,"sku":"XDZFL-38DF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-56DF","offer_id":56412439019825,"sku":"XDZFL-56DF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19df-correct-logo-v3.jpg?v=1790068387"},{"product_id":"exinda-ceiling-suspended-long-throw-jet-water-cooled-package-unit","title":"EXINDA Ceiling-Suspended Long-Throw Jet Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eCeiling-Suspended Long-Throw Jet Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,500–12,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\n\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\n\u003cp\u003eA ceiling-suspended indoor package with long-throw jet outlets for direct air delivery across large industrial spaces while keeping floor areas unobstructed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19DS\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-28DS\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e190 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-38DS\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,500 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤68 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1360×850×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e260 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFLB-56DS\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e12,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤69 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e2160×950×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e400 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow the system works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\n\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\n\u003ch2\u003eSelection guidance\u003c\/h2\u003e\n\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, external static pressure, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\n\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\n\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19DS","offer_id":56412439085361,"sku":"XDZFL-19DS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-28DS","offer_id":56412439118129,"sku":"XDZFLB-28DS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-38DS","offer_id":56412439150897,"sku":"XDZFLB-38DS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFLB-56DS","offer_id":56412439183665,"sku":"XDZFLB-56DS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19ds-correct-logo-v3.jpg?v=1790068402"},{"product_id":"exinda-ceiling-mounted-louvered-water-cooled-package-unit","title":"EXINDA Ceiling-Mounted Louvered Water-Cooled Package Unit","description":"\u003cp\u003e\u003cstrong\u003eCeiling-Mounted Louvered Water-Cooled Package Unit\u003c\/strong\u003e is a self-contained industrial water-cooled DX package unit designed for factories, workshops, warehouses and other large indoor spaces. The indoor package integrates the compressor, DX evaporator, water-cooled condenser, supply fan and controls. Condenser-water piping connects the unit to a remote adiabatic fluid cooler or a suitable central cooling-water system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling range:\u003c\/strong\u003e 19.5–56 kW   |   \u003cstrong\u003eAirflow:\u003c\/strong\u003e 5,000–8,000 m³\/h   |   \u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R410A   |   \u003cstrong\u003ePower:\u003c\/strong\u003e 380 V \/ 3 N~ \/ 50 Hz\u003c\/p\u003e\n\u003ch2\u003eProduct positioning and applications\u003c\/h2\u003e\n\u003cp\u003eA ceiling-mounted package with louvered discharge for direct, adjustable supply-air delivery in industrial buildings where floor space is limited.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing plants and production workshops\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics facilities\u003c\/li\u003e\n\u003cli\u003eLarge indoor work areas requiring sensible cooling and dehumidification\u003c\/li\u003e\n\u003cli\u003eProjects requiring separation of indoor supply air from the outdoor heat-rejection air stream\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel selection and technical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003cth\u003eSound\u003c\/th\u003e\n\u003cth\u003eWater connection\u003c\/th\u003e\n\u003cth\u003eIndoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eOutdoor unit W×D×H\u003c\/th\u003e\n\u003cth\u003eIndoor \/ outdoor weight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-19DB\u003c\/td\u003e\n\u003ctd\u003e19.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.28 kW\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e5,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤62 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e770×770×1330\u003c\/td\u003e\n\u003ctd\u003e180 \/ 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-28DB\u003c\/td\u003e\n\u003ctd\u003e28 kW\u003c\/td\u003e\n\u003ctd\u003e5.46 kW\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e6,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤63 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN32\u003c\/td\u003e\n\u003ctd\u003e1150×860×800\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e190 \/ 78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-38DB\u003c\/td\u003e\n\u003ctd\u003e38 kW\u003c\/td\u003e\n\u003ctd\u003e6.91 kW\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e7,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003e1360×850×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1450\u003c\/td\u003e\n\u003ctd\u003e260 \/ 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXDZFL-56DB\u003c\/td\u003e\n\u003ctd\u003e56 kW\u003c\/td\u003e\n\u003ctd\u003e11.46 kW\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003ctd\u003e8,000 m³\/h\u003c\/td\u003e\n\u003ctd\u003e≤67 dB(A)\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003ctd\u003e2160×950×760\u003c\/td\u003e\n\u003ctd\u003e970×970×1680\u003c\/td\u003e\n\u003ctd\u003e400 \/ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003csmall\u003eDimensions are in mm; weight is in kg. Ratings are based on condenser-water inlet\/outlet temperatures of 30\/35°C and indoor conditions of 27°C dry bulb \/ 19°C wet bulb.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow the system works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe indoor DX evaporator cools and dehumidifies the recirculated indoor air.\u003c\/li\u003e\n\u003cli\u003eThe water-cooled condenser transfers refrigerant heat to the condenser-water circuit.\u003c\/li\u003e\n\u003cli\u003eA remote adiabatic fluid cooler or central cooling-water system rejects that heat outdoors.\u003c\/li\u003e\n\u003cli\u003eThe outdoor heat-rejection air stream remains separate from the conditioned indoor supply air.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation and water system\u003c\/h2\u003e\n\u003cp\u003eProvide appropriately sized condenser-water piping, circulation pumps, water treatment, filtration, expansion provisions and controls according to the project design. Maintain service clearances and verify structure, drainage, electrical supply and airflow paths before installation.\u003c\/p\u003e\n\u003ch2\u003eSelection guidance\u003c\/h2\u003e\n\u003cp\u003eSelect the unit after checking the calculated sensible and latent cooling loads, required airflow, external static pressure, installation arrangement, sound target, entering-water temperature and available heat-rejection system. Contact EXINDA with the project schedule and design conditions for selection support.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a direct evaporative cooler?\u003c\/h3\u003e\u003cp\u003eNo. It is a water-cooled DX package unit. The indoor air passes across a DX evaporator; the condenser-water loop carries heat to a separate outdoor heat-rejection system.\u003c\/p\u003e\n\u003ch3\u003eCan it connect to a central cooling-water system?\u003c\/h3\u003e\u003cp\u003eYes, provided the available water temperatures, flow, pressure and water quality meet the project design requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich refrigerant and electrical supply are used?\u003c\/h3\u003e\u003cp\u003eThe listed models use R410A and 380 V \/ 3 N~ \/ 50 Hz power. Protection rating is IPX4 and appliance class is Class I.\u003c\/p\u003e\n\u003ch3\u003eHow should the model be selected?\u003c\/h3\u003e\u003cp\u003eUse a project cooling-load calculation and confirm airflow, water conditions, installation arrangement and sound requirements. Area-only rules of thumb are not sufficient for final selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a project selection?\u003c\/strong\u003e Send EXINDA your cooling load, design temperatures, building layout, airflow requirement and available condenser-water conditions.\u003c\/p\u003e","brand":"EXINDA","offers":[{"title":"XDZFL-19DB","offer_id":56412439216433,"sku":"XDZFL-19DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-28DB","offer_id":56412439249201,"sku":"XDZFL-28DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-38DB","offer_id":56412439281969,"sku":"XDZFL-38DB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"XDZFL-56DB","offer_id":56412439314737,"sku":"XDZFL-56DB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/exinda-xdzfl-19db-correct-logo-v3.jpg?v=1790068363"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/collections\/exinda-industrial-water-cooled-packaged-air-conditioners-collection.png?v=1790061815","url":"https:\/\/exindagroup.com\/it\/collections\/industrial-water-cooled-packaged-air-conditioners.oembed","provider":"EXINDA","version":"1.0","type":"link"}