{"product_id":"exinda-shc-40-ton-r454b-four-pipe-air-to-water-heat-pump-chiller-副本","title":"EXINDA 140kW R454B Four-Pipe Air-to-Water Heat Pump Chiller","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden @[53.5rem]\/main:[--thread-content-max-width:48rem] relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eEXINDA is a global HVAC manufacturer and system provider delivering R454B four-pipe air-to-water heat pump chillers for European commercial and institutional hydronic applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe EXINDA 140kW Four-Pipe Heat Pump Chiller provides chilled water and hot water simultaneously from a single outdoor unit. Its heat-recovery system supports buildings with concurrent cooling and heating demands while achieving a combined COP of up to 8.2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e Commercial Four-Pipe Air-to-Water Heat Pump Chiller\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Hydronic Cooling \/ Heating \/ Simultaneous Heating and Cooling\u003cbr\u003e\u003cstrong\u003eTechnology: \u003c\/strong\u003eR454B Dual DC Inverter EVI Scroll Compressor System\u003cbr\u003e\u003cstrong\u003ePower Supply: \u003c\/strong\u003e380V \/ 3-Phase \/ 50Hz\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e123kW nominal cooling capacity at 35°C ambient and 12°C\/7°C entering\/leaving water temperatures\u003c\/li\u003e\n\u003cli\u003e140kW heating capacity at 8°C\/6°C ambient and 41°C leaving-water condition\u003c\/li\u003e\n\u003cli\u003e119kW cooling and 168kW heating capacity during simultaneous heating and cooling operation\u003c\/li\u003e\n\u003cli\u003eCombined simultaneous heating and cooling COP up to 8.2\u003c\/li\u003e\n\u003cli\u003eCooling EER up to 10 BTU\/W and heating COP up to 3.64\u003c\/li\u003e\n\u003cli\u003eHot-water temperatures up to 60°C at ambient temperatures of -20°C or above\u003c\/li\u003e\n\u003cli\u003eHot-water temperatures up to 55°C from -25°C to -20°C ambient\u003c\/li\u003e\n\u003cli\u003eCooling operation from -20°C to 43°C ambient\u003c\/li\u003e\n\u003cli\u003eHeating operation from -25°C to 38°C ambient\u003c\/li\u003e\n\u003cli\u003eMinimum chilled-water leaving temperature of 4°C\u003c\/li\u003e\n\u003cli\u003eR454B low-GWP refrigerant with two independent refrigerant circuits\u003c\/li\u003e\n\u003cli\u003eDual DC inverter EVI scroll compressors with stepless capacity control\u003c\/li\u003e\n\u003cli\u003eFour-pipe configuration with independent heating and cooling heat exchangers\u003c\/li\u003e\n\u003cli\u003eHeat-recovery operation for buildings with simultaneous heating and cooling loads\u003c\/li\u003e\n\u003cli\u003eTwo EC inverter axial fans with a total airflow rate of 45,194 m³\/h\u003c\/li\u003e\n\u003cli\u003eSmart freeze protection and intelligent defrost control\u003c\/li\u003e\n\u003cli\u003eModular cascade control for up to 6 units\u003c\/li\u003e\n\u003cli\u003e2½-inch flanged hydronic connections\u003c\/li\u003e\n\u003cli\u003eSound power level of 86 dB(A) in cooling mode\u003c\/li\u003e\n\u003cli\u003eSuitable for hotels, schools, hospitals, offices, multi-residential buildings, industrial facilities, and other commercial hydronic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"EXINDA","offers":[{"title":"Default Title","offer_id":55585443021105,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/9074\/0529\/files\/EXINDA140kWR454BFour-PipeAir-to-WaterHeatPumpChiller_b276aee8-4d47-44b8-8926-d9d8aeb76319.png?v=1785813129","url":"https:\/\/exindagroup.com\/fr\/products\/exinda-shc-40-ton-r454b-four-pipe-air-to-water-heat-pump-chiller-%e5%89%af%e6%9c%ac","provider":"EXINDA","version":"1.0","type":"link"}